mshahin@digimeters.com (971) 4 2833 337
SGS SMART GRIDS SOLUTIONS
A Member of SGS Group of Companies
A Key Branch of SGS Inc., USA
SGS Technology Inc. SMART™ Electricity Devices
SGS's Smart Devices enable two-way power and information flows between the Distribution utility and the customer, where the Electric utilities are using the real-time information provided by smart Devices and other investments in the digital smart grid to improve the efficiency and reliability of the electric system.
SGS has introduced CT and direct connect Kwh meters that are among the first to meet the new European EN 50470-3 MID approval regulations. They are part of a new range being introduced by the company.
SGS can provide total solutions for the metering of electricity for all segments of the electricity market i.e. from generation and transmission to distribution. The company offers a range of individual devices for different levels of measurement, including residential, commercial, small and large industrial consumers, as well as for transmission and distribution networks.
SGS Smart Devices standardised under the; IEC, ANSI, FCC, DLMS/COSEM and NEMA specification for interoperability of open meters, open protocol to achieve the goal for real Smart Grid solutions.
Electricity Products Range
SGS's SMART MT and DZZ Series Single Phase PLC Electricity Devices for Smart Grid Application.
SMART MT and DDZ Series is a single tariff or Multi- Tariff Single-phase PLC device is used for measuring of active energy in single phase two-wire networks.
SMART MT and DDZ Series comply with both European (EN 50470-1 and EN 50470-3) and international (IEC 62052-11 and IEC 62053-21) standards, and are designed and manufactured in compliance with the ISO 9001-2 standard.
SMART MT A Multi-Tariff type meter uses for measuring of active energy. A multi-rate device, uses for measuring of active or active and reactive energy in two energy flow direct ions .
TECHNICAL DATA:
-
Accuracy class (kWh) A or B (by EN 50470-3) 2 or 1 (by IEC 62053-21)
-
Reference current Ib: 5 A, 10 A
-
Max current (Imax): 85 A, 100 A
-
Min. current: 0.05 Ib
-
Starting current: 0.004 Ib
-
Reference voltage Un: 220V–240V
-
Voltage range: 0.8 Un .... 1.15 Un
-
Reference frequency:.50 or 60Hz
-
Operating temp. range.: -40°C ,+70°C (LCD: -25°C,+70°C
-
Storage temperature: -40°C ... +85°C
-
Dielectric strength: 4 kV, 50 Hz, 1 min
-
Impulse voltage: < 8 kV
-
Surge: < 6 kV
-
Short-circuit current: 30 Imax
-
EMC: better than requested in IEC 62053-21
-
Optical port :IEC 62056-21
-
Dimensions: 230 x 130 x 44 mm
-
Mass: approx. 0,55kg
Communication:
-
Optical port IEC 62056 – 21: for local meter programming and data downloading.
-
PLC Built-In modem
-
Multi-tariff registration:
-
Internal time switch.
-
Programmable number of rates (1 -4 rates)
SGS's SMART MT Series Three Phase PLC Residential Electricity Meters For Smart Grid Application.
SGS's SMART Poly Phase 3 or 4 Wires Watt-hour PLC device: CT & WC Type used for measurement of active or active andreactive energy in three phase four wire, three-wire networks. They can be connected directly or via CT. The device can also be used in single phase two-wire networks ( US Version) , It is comply with IEC 62052-11 and IEC 620532 standards, and are designed and manufactured in compliance with the ISO 9001-2 and DLMS/COSEM standard.
SGS SMART MT10, multi-rate device ,uses for measuring of active or active and reactive energy in two energy flow direct ions . SMART MT, TB Series is a Poly phase PLC device comply with both European (EN 50470-1and EN 50470-3) and international Standards :
TECHNICAL DATA:
-
Rated voltage: 3 x 230/400 V, 3x230 V, 230 V Voltage range : 0.8 Un ..1.15 Un
-
Basic current 5, 10, 15, 20 A (direct connected meters) 1 A (CT operated meters)
-
Max. current Imax: 40, 60, 80, 85, 100, 120A Min. current : .0.05 Ib, Short-circuit current : 30 Imax
-
Frequency: 50 Hz or 60 Hz ( ± 2%)
-
Power burden: Current circuit burden :<0.5 VA,Voltage circuit burden : <1 W/10 VA
-
Starting current:: 0.004 Ib (directly connected meters) , 0.002 Ib (CT operated meters)
-
Normal operation temperature: -20°C ~ + 55°C
-
Limit operation temperature: -20°C ~ + 60°C
-
Relative humidity: 95%
-
RTC accuracy(daily error): ≤0.5S (23°C)
-
Communication protocol: ANSI, Multi-Protocol PLC, DLMS/COSEM as well as PLC/FCC
-
Accuracy Class: A or B (by EN 50470-3) 2 or (by IEC 62053-21) (kvarh 3 or 2 (by IEC 62053-23)
-
Dielectric strength : 4 kV, 50 Hz, 1 min
-
Impulse voltage : main circuits 12 kV (aux. circuits: 6 kV), 1.2/50 μs
-
EMC: Burst(IEC 61000-4-4) : 6 kV
-
Optical port (Optional) : IEC 62056-21 (DLMS/COSEM)
SGS's SMART ZX Series Three Phase PLC Commercial Electricity Devices for Smart Grid Application.
CSC's SMART Poly Phase 3 or 4 Wires PLC Watt-hour device: CT & WC Type is multi-functional smart energy Device able to measure bi-directional active and reactive energy, apparent energy and four quadrant reactive energy. Equipped with several input and output ports, this meter is able to connect with various communication modules flexibly. It also has the functions of remote connection/disconnection. Conform to the IEC62056 standard and DLMS/COSEM protocol, it is widely used in commercial and residential sectors at residential and commercial buildings, factories and power stations.
TECHNICAL DATA:
-
Rated voltage: 3 x 230/400 V, 3x230 V, 230 V Voltage range : 0.8 Un ..1.15 Un
-
Basic current 5, 10, 15, 20 A (direct connected meters) 1 A (CT operated meters)
-
Max. current Imax: 40, 60, 80, 85, 100, 120A Min. current : .0.05 Ib, Short-circuit current : 30 Imax
-
Frequency: 50 Hz or 60 Hz ( ± 2%)
-
Power burden: Current circuit burden :<0.5 VA,Voltage circuit burden : <1 W/10 VA
-
Starting current:: 0.004 Ib (directly connected meters) , 0.002 Ib (CT operated meters)
-
Normal operation temperature: -20°C ~ + 55°C
-
Limit operation temperature: -20°C ~ + 60°C
-
Relative humidity: 95%
-
RTC accuracy(\(\(\(daily error): ≤0.5S (23°C)
-
Communication protocol: ANSI, Multi-Protocol PLC, DLMS/COSEM as well as PLC/FCC
-
Accuracy Class: A or B (by EN 50470-3) 2 or (by IEC 62053-21) (kvarh 3 or 2 (by IEC 62053-23)
-
Dielectric strength : 4 kV, 50 Hz, 1 min
-
Impulse voltage : main circuits 12 kV (aux. circuits: 6 kV), 1.2/50 μs
-
EMC: Burst(IEC 61000-4-4) : 6 kV
-
Optical port (Optional) : IEC 62056-21 (DLMS/COSEM)
SMArT ZX 600 ALPHA
SGS's SMART MF Series Three Phase PLC Industrial Electricity Devices for Smart Grid Application.
SMArT ZX 600 ALPHA
SGS's SMART Poly Phase 3 or 4 Wires PLC Watt-hour device: CT & DC Type used for measurement of active or active andreactive energy in three phase four wire, three-wire networks. They can be connected directly or via CT. The device can also be used in single phase two-wire networks ( US Version) , and it is comply with IEC 62052-11 and IEC 620532 standards, and are designed and manufactured in compliance with the ISO 9001-2 and DLMS/COSEM standard.
SGS SMART MT Series, multi-rate PLC Devices ,uses for measuring of active or active and reactive energy in two energy flow direct ions . SMART MT, TB Series is a Poly phase meter comply with both European (EN 50470-1and EN 50470-3) and international Standards :
TECHNICAL DATA:
-
Rated voltage: 3 x 230/400 V, 3x230 V, 230 V Voltage range : 0.8 Un ..1.15 Un
-
Basic current 5, 10, 15, 20 A (direct connected meters) 1 A (CT operated meters)
-
Max. current Imax: 40, 60, 80, 85, 100, 120A Min. current : .0.05 Ib, Short-circuit current : 30 Imax
-
Frequency: 50 Hz or 60 Hz ( ± 2%)
-
Power burden: Current circuit burden :<0.5 VA,Voltage circuit burden : <1 W/10 VA
-
Starting current:: 0.004 Ib (directly connected meters) , 0.002 Ib (CT operated meters)
-
Normal operation temperature: -20°C ~ + 55°C
-
Limit operation temperature: -20°C ~ + 60°C
-
Relative humidity: 95%
-
RTC accuracy(daily error): ≤0.5S (23°C)
-
Communication protocol: ANSI, Multi-Protocol PLC, DLMS/COSEM as well as PLC/FCC
-
Accuracy Class: A or B (by EN 50470-3) 2 or (by IEC 62053-21) (kvarh 3 or 2 (by IEC 62053-23)
-
Dielectric strength : 4 kV, 50 Hz, 1 min
-
Impulse voltage : main circuits 12 kV (aux. circuits: 6 kV), 1.2/50 μs
-
EMC: Burst(IEC 61000-4-4) : 6 kV
-
Optical port (Optional) : IEC 62056-21 (DLMS/COSEM)